Specification Sheet
WB-455, WB-555, WB-655
Horizontal Water Bath Vaporizer
Horizontal Water Bath Vaporizer
Type | Horizontal Water Bath LPG Vaporizer | |||
Model Number | WB-455 | WB-555 | WB-655 | |
Capacity | gph | 455 | 555 | 655 |
kg/h | 873 | 1065 | 1257 | |
MMBTU/h | 42 | 51 | 60 | |
kW | 12300 | 14950 | 17590 | |
Water Tank Capacity |
220 Gallons (0.83 m3) to Fill Plug |
|||
Burner Type |
Forced Draft Power Burner, 4-inch Maxon Tube-O-Therm or similar; |
|||
Burner Capacity | MMBTU/h | 0.540 | 0.660 | 0.780 |
kW | 158 | 193 | 229 | |
Design Temperature | 650 °F (343 °C) | |||
Design Pressure | 250 PSIG (17.2 bar) | |||
Manufactured Construction | Vaporizing Tube Conforms to ASME Boiler & Pressure Vessel Code, Section VIII, Division I. Conforms to latest edition of NFPA #58. Power type Burner; Electronic Flame Safeguard; Electronic System Controls with Siemens or Allen-Bradley PLC and Operator Interface with color LCD display and touch screen. First-Outage Monitor (Alarm History with date and time stamp) and graphic trend recording. |
|||
Approvals | Factory Mutual (FM) or Industrial Risk Insurers (IRI). Canadian Standards Association (CSA). Optional European CE Approval including PED, ATEX, and all other applicable Directives. |
|||
Standard Safety Features
|
|
|||
Liquid Inlet Connection | 1" 300# Raised Face ANSI Flange (Optional DN25 PN40 DIN Flange) | |||
Liquid Inlet Valve | 250 psi Flanged Direct-Acting Solenoid Valve; with Check Valve Bypass; Ball Valve for Manual Shutoff. | |||
Vapor Outlet | 2" 300# Raised Face ANSI Flange (Optional DN50 PN25 DIN Flange) | |||
PLC and Electronic Operator Interface |
|
|||
Electrical Requirement |
380/400/480VAC 50/60Hz; 25A Circuit; 3-Phase; |
|||
Circuit Protection | Automatic Circuit Breakers with Manual Reset for all AC and DC Circuits; Main Breaker/Disconnect. | |||
Design Criteria, Vaporizer | Designed and manufactured to comply with the latest edition of NFPA Pamphlet 58; FM approved. European CE Mark available. | |||
Design Criteria, LPG Heat Exchanger | Designed and manufactured in compliance with ASME Boiler and Pressure Vessel Code Section VIII, Division 1. ASME U-Stamp available. CE-marked vaporizers comply with European PED. |
|||
Design Criteria, Control Panel | General-purpose wiring, compliant with National Electric Code (NEC; NFPA #70). UL-508A available. CE-marked vaporizers comply with all applicable European Directives. | |||
Mechanical Construction, Skid Base |
1/4-inch (6.35mm) Steel Deck Plate on all-welded 6-inch (150mm) Tubular Frame with Cross-Members; Lifting Lugs; mechanically cleaned, primed, and painted (AES Blue, RAL 5015). | |||
Mechanical Construction, Bath Box |
1/4-inch (6.35mm) all-welded steel walls with internal stiffeners and supports for LPG Heat Exchanger. | |||
Mechanical Construction, Water Circulating Pump |
Wet-Cartridge Type Hot-Water Circulator installed inside Vaporizer Control Room. Diffuser in Water Bath. | |||
Mechanical Construction, Insulation |
Mineral Fiber insulation with Aluminum backing on side walls, top plate, and front and rear wall. | |||
Mechanical Construction, Bath Box Cover |
16-gauge (1.5mm) Sheet Metal Panels, powder-coated (gray RAL 9002). | |||
Mechanical Construction, Control Room |
12-gauge (2.7mm) Sheet Metal, primed and painted (AES Blue, RAL 5015); lockable door; louvers, window insert. | |||
Mechanical Construction, Dimensions |
72 x 138 x 112 (inches; W x L x H) |
|||
Mechanical Construction, Shipping Weight |
5400 lbs |
|||
Catalog Drawing | Click here for Catalog Drawing (Page 8 of Brochure) |