Alternate Energy Systems, Inc.
LPG Vaporizers - LP/Air Blenders - Gas/Gas Blenders - NatGas Backup Systems - PeakShaving Systems
Price List - No Longer Updated Online
Accessories for LPG Systems, Liquid Transfer Pumps, AEP-Series

Downloads

 

Corken Duplex Transfer PumpPump System Features

  • Capacities from 5 gpm to 150+ gpm
  • Direct-Drive Turbine Pumps for small capacity
  • Belt-Driven Sliding-Vane Pumps for large capacity
  • Skid-mounted
  • Primed and Painted (Marine Grade)
  • Inlet Strainer
  • Flexible Inlet/Outlet/Bypass Connections
  • All-welded piping
  • Backpressure Regulator
  • Differential Pressure Regulator
  • Summer-Bypass
  • Liquid-filled Pressure Gauges
  • Single-Pump Systems
  • Duplex-Pump Systems
  • Corken or Blackmer Pumps
  • US or International Voltages
  • Multiple starter options
  • Integration with SNG System Controls
  • Ex-proof Motors Class I, Div. 1, Group D (Flame-Proof)

LPG Transfer Pumps, as the name implies, are used to transfer LPG from the storage tanks to the vaporizer. In systems with Venturi LPG/air mixing systems, they are also responsible for maintaining the pressure needed for optimum and efficient function of the Venturi tubes.

All AES pump packages are mounted on steel skids, and are primed and painted. They are equipped with differential pressure regulator, constant pressure regulator, strainer, isolation valves, by-pass loops ("Summer-Bypass"), liquid filled pressure gauges, and all other components required for safe operation.

Smaller pumps up to 12 GPM are single phase AC 115/230V 50/60Hz service. Larger pumps are 3-phase AC 460V 60Hz or 400/415V 50Hz and require magnetic motor starters with overload protection. Pumps up to 18 GPM are direct-drive turbine type (electric motor directly coupled to pump). Larger pumps are belt driven, sliding-vane type.

A back pressure regulator provides stable delivery pressure by returning excess pump capacity to the storage tank.

All systems are supplied with an explosion proof motor to meet Class I, Div. 1, Group D (Flame-Proof) requirements.

Magnetic motor starters can be supplied either as a separate component, installed on the pump skid, or integrated with the system controls. If integrated with the system controls, a Start/Stop station at the pump skid is provided for local pump control.

All AES pump systems are available with either Corken or Blackmer pumps, and can be configured for various voltages and for 50 Hz or 60 Hz.

The purpose of Duplex Pump Systems is to provide maximum redundancy. They are therefore manufactured as individual pumps that only share a common skid. All bypass and isolation valves exist in duplicate. Each pump can be completely isolated so that maintenance and repair work on this pump does not affect the other pump, or the system availability.

Integrated pumps can also be equipped with an automatic start/stop function in response to the pressure in the storage tank(s). The price adder for these options is shown below (in section "Motor Starters and other Options").

 
 
 
 
 

Back To Top

Motor Starters and Other Options for Single-Phase Pumps (fits both Blackmer and Corken Pumps)

Liquid Transfer Pumps with single-phase motors can be supplied with a simple, explosion-proof ON/OFF switch that is integrated into the junction box directly at the pump motor. If the pump control is desired to be integrated with the vaporizer- or vaporizer/blender control system (for example to facilitate remote monitoring and control), pumps with single-phase motors can also be equipped with contactors.
 
It is recommended that contactor-equipped pumps are also equipped with a local Start/Stop station that allows pump control from the pump location. AES Start/Stop stations are configured with an explosion-proof enclosure (Class I, Div 1, Group D [Flame-Proof]), green START button, red STOP button, and amber pilot light (pump ready to be started).
  
The operation of single-phase pumps with contactors can also be automated in response to the pressure in the storage tanks (pump will start automatically if tank pressure falls below an adjustable setpoint, and stays on until the tank pressure has recovered above a second adjustable setpoint).

Description (for Single-Phase Motors)

Single-Pump Dual-Pump

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in vaporizer- or vaporizer/blender control panel; terminals for AC feed, pump connection, and control voltage.

US-$ US-$

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in separate enclosure;supplied loose for indoor field installation (NEMA 1).

US-$ US-$

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in separate enclosure;supplied loose for outdoor field installation (NEMA 3R).

US-$ US-$

Automatic Start/Stop Function and Control System Integration  (for Single-Phase Motors)

Single-Pump Dual-Pump

Integration of pump control in vaporizer- or vaporizer/blender control system; includes Start/Stop Station, Explosion-Proof, NEMA 7,9,3R Outdoor Enclosure; Start/Stop Station; Pilot Light; installed at pump skid.

US-$ US-$

Automatic pump start/stop in response to pressure in storage tank(s); includes option "Integration of pump control in vaporizer- or vaporizer/blender control system"; includes Rosemount pressure transmitter in pump inlet.

US-$ US-$

Start/Stop Stations (for Single-Phase Motors)

Single-Pump Dual-Pump

Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

US-$ US-$

Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; and integrated ESD Station(Mushroom Button); supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

US-$ US-$

 

 

 

Back To Top

Motor Starters and Other Options for Three-Phase Pumps (fits both Blackmer and Corken Pumps)

Liquid Transfer Pumps with 3-phase motors always require magnetic motor starters. All AES magnetic motor starters are configured with contactor, solid state motor overload protection, service-disconnect function, and manual reset.

AES Starter Packages will be configured to match the selected pump size and motor, and are available for indoor installation, outdoor installation, and explosion-proof Class I, Div 1, Group D [Flame-Proof] installations. It is recommended that all pumps are also equipped with a local Start/Stop station that allows pump control from the pump location. AES Start/Stop stations are configured with an explosion-proof enclosure (Class I, Div 1, Group D [Flame-Proof]), green START button, red STOP button, and amber pilot light (pump ready to be started).

All types can also be integrated into the vaporizer or vaporizer/blender control system for remote monitoring and control of the pump operation.

The pump operation can also be automated in response to the pressure in the storage tanks (pump will start automatically if tank pressure falls below an adjustable setpoint, and stays on until the tank pressure has recovered above a second adjustable setpoint).

Starter Packages Description (for Three-Phase Motors)

Single-Pump Dual-Pump

Starter Package, Non-Explosion-Proof; installed in separate enclosure without Start/Stop Station; supplied loose for indoor field installation (NEMA 1 Indoor Enclosure).

up to
10 HP
US-$ US-$
over
10 HP
US-$ US-$

Starter Package, Non-Explosion-Proof; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for indoor field installation (NEMA 1Indoor Enclosure).

up to
10 HP
US-$ US-$
over
10 HP
US-$ US-$

Starter Package, Non-Explosion-Proof; installed in separate enclosure without Start/Stop Station; supplied loose for outdoor field installation (NEMA 3R Outdoor Enclosure).

up to
10 HP
US-$ US-$
over
10 HP
US-$ US-$

Starter Package, Non-Explosion-Proof; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for outdoor field installation (NEMA 3ROutdoor Enclosure).

up to
10 HP
US-$ US-$
over
10 HP
US-$ US-$

Starter Package, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for outdoor field installation (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

up to
10 HP
US-$ US-$
over
10 HP
US-$ US-$

Automatic Start/Stop Function and Control System Integration (for Three-Phase Motors)

Single-Pump Dual-Pump

Integration of pump control in vaporizer- or vaporizer/blender control system; includes Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; green START button; red STOP button; amber Pilot Light; installed in separate enclosure at pump skid.

US-$ US-$

Automatic pump start/stop in response to pressure in storage tank(s); includes option "Integration of pump control in vaporizer- or vaporizer/blender control system"; includes Rosemount pressure transmitter in pump inlet.  

US-$ US-$

Start/Stop Stations (for Three-Phase Motors)

Single-Pump Dual-Pump

Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

US-$ US-$

Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; and integrated ESD Station("Mushroom" Button); supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

US-$ US-$

Starter Installation (for Three-Phase Motors)

Single-Pump Dual-Pump

Installation of Non-Explosion-Proof Motor Starter inside a Vaporizer Control Room; includes separate conduit entries in walls of vaporizer control room for power feed, connection to pump, and connection to Start/Stop Station.

US-$ US-$

Installation of Non-Explosion-Proof Motor Starter in a separate enclosure outside a Vaporizer Control Room; includes separate conduit entries for power feed, connection to pump, and connection to Start/Stop Station.

US-$ US-$

Installation of Explosion-Proof Motor Starter at pump skid; includes mounting frame for ex-proof starter enclosure; includes conduit connection between starter enclosure and motor junction box; includes 18-inch flex conduit.

US-$ US-$

Last Update 31 JAN 2019

© Copyright 2006 ..... 2020 by Alternate Energy Systems, Inc. - All Rights reserved.